[OmniOS-discuss] Overheating faults with ST4000NM0023

Richard Elling richard.elling at richardelling.com
Tue Apr 22 20:08:57 UTC 2014


On Apr 22, 2014, at 10:58 AM, Saso Kiselkov <skiselkov.ml at gmail.com> wrote:

> On 4/22/14, 5:03 PM, Schweiss, Chip wrote:
>> Are you sure you have SAS multipath disabled on the disk you are trying
>> to flash?
>> 
>> I couldn't get these to flash at all with MP enabled.  I too kept
>> getting OS related errors.
>> 
>> For one system I did an stmsboot -d, for another I just pulled one of
>> the SAS cables to each JBOD.
> 
> Oh, you're right, hadn't considered that. I'll have to try this out,
> even though it means downtime.

mpathadm(1m) allows you to enable/disable paths on the fly, without pulling cables.
 -- richard

--

Richard.Elling at RichardElling.com
+1-760-896-4422