[OmniOS-discuss] live lsi firmware upgrade P17->P19
Schweiss, Chip
chip at innovates.com
Thu Dec 11 18:30:45 UTC 2014
On Thu, Dec 11, 2014 at 9:44 AM, Tobias Oetiker <tobi at oetiker.ch> wrote:
> I am looking at upgrading the firmware of our LSI HBAs to P19 since
> we suspect that our use of P17 is the cause for disk timeouts we
> are seeing every few weeks.
>
> I am wondering, is it save to flash the HBAs from a running omnios system,
> and if so, has anyone written some notes down on the process and
> tools to use?
>
>
I don't believe that is possible on a live system. I have upgraded using
the Solaris sas2flash utility on a system with the pool exported. The
last step of the flash function is to reset the adapter which fails
requiring the system to be rebooted.
What I haven't tried is disconnecting the SAS cables then applying the
update. I suspect this may work, but is only a useful method if you have
redundant SAS paths and can do one HBA at a time.
These issues are why I run HA systems and can migrate my pools from server
to server and perform maintenance at a leisurely pace and confirm
everything is the way I want it before putting the server back in service.
-Chip
> cheers
> tobi
>
>
> --
> Tobi Oetiker, OETIKER+PARTNER AG, Aarweg 15 CH-4600 Olten, Switzerland
> www.oetiker.ch tobi at oetiker.ch +41 62 775 9902
>
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <https://omniosce.org/ml-archive/attachments/20141211/d09ba6cd/attachment.html>
More information about the OmniOS-discuss
mailing list