Hi guys,

We have ~ 10 OmniOS powered ZFS storage arrays used to drive Virtual Machines under XenServer + VMWare using Infiniband interconnect.

Our usual recipe is to use either LSI HBA or Areca Cards in pass through mode using internal drives SAS drives..

This has worked flawlessly with Omnios 6/8.

Recently we deployed a slightly different configuration

HP DL380 G6
64GB ram
X5650 proc
LSI 9208-e card
HP MDS 600 / SSA 70 external enclosure
30 TOSHIBA-MK2001TRKB-1001-1.82TB SAS2 drives in mirrored configuration.

despite the following message in dmesg the array appeared to be working as expected

scsi: [ID 365881 kern.info] /pci at 0,0/pci8086,340f at 8/pci1000,30b0 at 0 (mpt_sas1):
May 13 04:01:07 s6      Log info 0x31140000 received for target 11.

Despite this message we pushed into production and whilst the performance of the array has been good, as soon as we perform high write IO performance goes from 22k IOPS down to 100IOPS, this causes the target to disconnect from hypervisors and general mayhem ensues for the VMs.\

During this period where performance degrades, there are no other messages coming into dmesg.

Where should we begin to debug this? Could this be a symptom of not enough RAM? We have flashed the LSI cards to the latest firmware with no change in performance. 

Thanks in advance!