[OmniOS-discuss] Comstar Disconnects under high load.

David Bomba turbo124 at gmail.com
Mon May 12 22:34:43 UTC 2014


Previous configurations were

HP DL180 G6
96GB RAM
Areca 1882-ix using passthrough
25x600Gb Toshiba MBF2600RC SAS 10k drives in mirrored config
L5640 Proc

We have 4 of these using a mixture of 006 and 008

New hardware runs 008.

On 13/05/2014, at 8:23 AM, Dan McDonald wrote:

> 
> On May 12, 2014, at 6:13 PM, David Bomba <turbo124 at gmail.com> wrote:
> 
>> Hi guys,
>> 
>> We have ~ 10 OmniOS powered ZFS storage arrays used to drive Virtual Machines under XenServer + VMWare using Infiniband interconnect.
>> 
>> Our usual recipe is to use either LSI HBA or Areca Cards in pass through mode using internal drives SAS drives..
>> 
>> This has worked flawlessly with Omnios 6/8.
>> 
>> Recently we deployed a slightly different configuration
>> 
>> HP DL380 G6
>> 64GB ram
>> X5650 proc
>> LSI 9208-e card
>> HP MDS 600 / SSA 70 external enclosure
>> 30 TOSHIBA-MK2001TRKB-1001-1.82TB SAS2 drives in mirrored configuration.
> 
> 1.) What was your previous configuration?  And running 006 or 008?
> 
> 2.) What is running on your new HW?  006 or 008?
> 
> Dan
> 



More information about the OmniOS-discuss mailing list