[OmniOS-discuss] how many HBAs my system have ?
Thomas Wagner
tom-omnios-discuss at tom.bn-ulm.de
Fri Oct 3 14:14:37 UTC 2014
I like the display of "cfgadm".
cfgadm
Ap_Id Type Receptacle Occupant Condition
sata2/0::dsk/c2t0d0 disk connected configured ok
sata2/1::dsk/c2t1d0 disk connected configured ok
sata2/2::dsk/c2t2d0 disk connected configured ok
sata2/3::dsk/c2t3d0 cd/dvd connected configured ok
sata2/4::dsk/c2t4d0 disk connected configured ok
sata2/5::dsk/c2t5d0 disk connected configured ok
In my system the controller is the onboard SATA, numbered as "sata2" with
6 ports.
Note: Sometimes a controller might be present, but no
driver attached. Then you don't see that on the list.
The cfgadm manpage has examples how controllers are
displayed (e.g. just Ap_Id is "c0").
To configure a controller you can run e.g. cfgadm -c configure c1
(controller numbers are incremented, getting a symlink
in /dev/cfg/ and registered in /etc/path_to_inst.)
So in the example you would have two, the first controllert
already linked to /dev/cfg/c0 and the second controller being
unconfigured, getting now the /dev/cfg/c1 link.
Else, the best source is still "/usr/sbin/prtconf -vp | ggrep -2 model",
even if there is too much information. It just never lies, as
it displays all the PCI informations.
Regards
Thomas
On Fri, Oct 03, 2014 at 10:25:35AM -0300, F??bio Rabelo wrote:
> How can I check how many HBA controlres do I have connected in a
> system, if this system are in a ( very ) remote location, and I just
> have SSH available ?
>
> prtconf -v returns too many noise !
>
> prtconv -v |grep RAID returns only one line ...
>
> There is an easy way ?
>
>
> Fábio Rabelo
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>
--
--
Thomas Wagner
------------------------------------------------------------------------
Service rund um UNIX(TM), Wagner Network Services, Thomas Wagner
Solaris(TM), Linux(TM) Eschenweg 21, 89174 Altheim, Germany
Novell(TM), Windows(TM) TEL: +49-731-9807799, FAX: +49-731-9807711
Telekommunikation, LAN, MOBILE/CELL: +49-171-6135989
Internet-Service, Elektronik EMAIL: wagner at wagner-net.com
More information about the OmniOS-discuss