[OmniOS-discuss] Fault Manager component could not load
Matthew Lagoe
matthew.lagoe at subrigo.net
Tue Sep 23 00:44:57 UTC 2014
I tried to add "setprop temp-multiple 0" to
/usr/lib/fm/fmd/plugins/disk-transport.conf due to a bug in Seagate drives,
however when I start up the machine with that configuration in it I get the
following error, if anyone has any ideas what the cause could be.
Thanks
--------------- ------------------------------------ --------------
---------
TIME EVENT-ID MSG-ID
SEVERITY
--------------- ------------------------------------ --------------
---------
Sep 22 17:10:10 e0719be1-fe87-6a27-cb4c-aaf2f8902a13 FMD-8000-3F Minor
Host : stor10
Platform : PowerEdge-R720 Chassis_id : FCNH3W1
Product_sn :
Fault class : defect.sunos.fmd.config
Affects : fmd:///module/disk-transport
faulted and taken out of service
FRU : None
faulty
Description : A Solaris Fault Manager component could not load due to an
erroroneous configuration file. Refer to
http://illumos.org/msg/FMD-8000-3F for more information.
Response : The module has been disabled. Events destined for the module
will be saved for manual diagnosis.
Impact : Automated diagnosis and response for subsequent events
associated
with this module will not occur.
Action : Use fmdump -v -u to locate the module. Use fmadm load
to load the module after repairing its configuration.
More information about the OmniOS-discuss
mailing list