[OmniOS-discuss] Multiple faulty SSD's ?
Shaun McGuane
shaun at rackcentral.com
Tue Jul 26 00:24:21 UTC 2016
Hi List,
I want to report very strange SSD behaviour on a new pool I setup.
The hardware is a HP DL180 G6 Server with the LSI 9207-8i Card
And 8x 1TB Samsung SSD Pro drives. Running omnios-10b9c79
All the drives are brand spanking new setup in a raidz2 array.
Within 2 months the below has happened and there has been very
Little use on this array.
pool: SSD-TANK
state: DEGRADED
status: One or more devices are faulted in response to persistent errors.
Sufficient replicas exist for the pool to continue functioning in a
degraded state.
action: Replace the faulted device, or use 'zpool clear' to mark the device
repaired.
scan: scrub repaired 23K in 1h12m with 0 errors on Mon Jul 25 20:13:04 2016
config:
NAME STATE READ WRITE CKSUM
SSD-TANK DEGRADED 1 67 35
raidz2-0 DEGRADED 4 72 113
c5t500253884014D0D3d0 ONLINE 0 0 2
c5t50025388401F767Ad0 DEGRADED 0 0 19 too many errors
c5t50025388401F767Bd0 FAULTED 0 0 0 too many errors
c5t50025388401F767Dd0 ONLINE 0 0 0
c5t50025388401F767Fd0 ONLINE 0 0 1
c5t50025388401F7679d0 ONLINE 0 0 2
c5t50025388401F7680d0 REMOVED 0 0 0
c5t50025388401F7682d0 ONLINE 0 0 1
Can anyone suggest why I would have this problem where I am seeing CKSUM errors
On most disks and while only one has faulted others have been degraded or removed.
Thanks
Shaun
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <https://omniosce.org/ml-archive/attachments/20160726/ab74f7ac/attachment-0001.html>
More information about the OmniOS-discuss
mailing list