[OmniOS-discuss] Multiple faulty SSD's ?
Piotr Jasiukajtis
estibi at me.com
Tue Jul 26 17:28:45 UTC 2016
You may want to force the driver to use 4k instead of 512b for those drivers and create a new pool:
https://github.com/joyent/smartos-live/commit/dd25937d2f9725def16f5e8dbb16a8bcbc2213d5
--
Piotr Jasiukajtis
> On 26 Jul 2016, at 02:24, Shaun McGuane <shaun at rackcentral.com> wrote:
>
> Hi List,
>
> I want to report very strange SSD behaviour on a new pool I setup.
>
> The hardware is a HP DL180 G6 Server with the LSI 9207-8i Card
> And 8x 1TB Samsung SSD Pro drives. Running omnios-10b9c79
>
> All the drives are brand spanking new setup in a raidz2 array.
>
> Within 2 months the below has happened and there has been very
> Little use on this array.
>
> pool: SSD-TANK
> state: DEGRADED
> status: One or more devices are faulted in response to persistent errors.
> Sufficient replicas exist for the pool to continue functioning in a
> degraded state.
> action: Replace the faulted device, or use 'zpool clear' to mark the device
> repaired.
> scan: scrub repaired 23K in 1h12m with 0 errors on Mon Jul 25 20:13:04 2016
> config:
>
> NAME STATE READ WRITE CKSUM
> SSD-TANK DEGRADED 1 67 35
> raidz2-0 DEGRADED 4 72 113
> c5t500253884014D0D3d0 ONLINE 0 0 2
> c5t50025388401F767Ad0 DEGRADED 0 0 19 too many errors
> c5t50025388401F767Bd0 FAULTED 0 0 0 too many errors
> c5t50025388401F767Dd0 ONLINE 0 0 0
> c5t50025388401F767Fd0 ONLINE 0 0 1
> c5t50025388401F7679d0 ONLINE 0 0 2
> c5t50025388401F7680d0 REMOVED 0 0 0
> c5t50025388401F7682d0 ONLINE 0 0 1
>
> Can anyone suggest why I would have this problem where I am seeing CKSUM errors
> On most disks and while only one has faulted others have been degraded or removed.
>
> Thanks
> Shaun
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
More information about the OmniOS-discuss
mailing list