[OmniOS-discuss] Multiple faulty SSD's ?
Piotr Jasiukajtis
estibi at me.com
Tue Jul 26 18:30:57 UTC 2016
I don’t know a root cause, but it’s better to have a workaround than a corrupted pools.
--
Piotr Jasiukajtis
> On 26 Jul 2016, at 20:06, Dan McDonald <danmcd at omniti.com> wrote:
>
> I wonder if those sd.conf changes should be upstreamed or not?
>
> Dan
>
> Sent from my iPhone (typos, autocorrect, and all)
>
>> On Jul 26, 2016, at 1:28 PM, Piotr Jasiukajtis <estibi at me.com> wrote:
>>
>> You may want to force the driver to use 4k instead of 512b for those drivers and create a new pool:
>>
>> https://github.com/joyent/smartos-live/commit/dd25937d2f9725def16f5e8dbb16a8bcbc2213d5
>>
>> --
>> Piotr Jasiukajtis
>>
>>> On 26 Jul 2016, at 02:24, Shaun McGuane <shaun at rackcentral.com> wrote:
>>>
>>> Hi List,
>>>
>>> I want to report very strange SSD behaviour on a new pool I setup.
>>>
>>> The hardware is a HP DL180 G6 Server with the LSI 9207-8i Card
>>> And 8x 1TB Samsung SSD Pro drives. Running omnios-10b9c79
>>>
>>> All the drives are brand spanking new setup in a raidz2 array.
>>>
>>> Within 2 months the below has happened and there has been very
>>> Little use on this array.
>>>
>>> pool: SSD-TANK
>>> state: DEGRADED
>>> status: One or more devices are faulted in response to persistent errors.
>>> Sufficient replicas exist for the pool to continue functioning in a
>>> degraded state.
>>> action: Replace the faulted device, or use 'zpool clear' to mark the device
>>> repaired.
>>> scan: scrub repaired 23K in 1h12m with 0 errors on Mon Jul 25 20:13:04 2016
>>> config:
>>>
>>> NAME STATE READ WRITE CKSUM
>>> SSD-TANK DEGRADED 1 67 35
>>> raidz2-0 DEGRADED 4 72 113
>>> c5t500253884014D0D3d0 ONLINE 0 0 2
>>> c5t50025388401F767Ad0 DEGRADED 0 0 19 too many errors
>>> c5t50025388401F767Bd0 FAULTED 0 0 0 too many errors
>>> c5t50025388401F767Dd0 ONLINE 0 0 0
>>> c5t50025388401F767Fd0 ONLINE 0 0 1
>>> c5t50025388401F7679d0 ONLINE 0 0 2
>>> c5t50025388401F7680d0 REMOVED 0 0 0
>>> c5t50025388401F7682d0 ONLINE 0 0 1
>>>
>>> Can anyone suggest why I would have this problem where I am seeing CKSUM errors
>>> On most disks and while only one has faulted others have been degraded or removed.
>>>
>>> Thanks
>>> Shaun
>>> _______________________________________________
>>> OmniOS-discuss mailing list
>>> OmniOS-discuss at lists.omniti.com
>>> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>>
>> _______________________________________________
>> OmniOS-discuss mailing list
>> OmniOS-discuss at lists.omniti.com
>> http://lists.omniti.com/mailman/listinfo/omnios-discuss
More information about the OmniOS-discuss
mailing list