[OmniOS-discuss] [SPAM] Mapping LSI SAS Target numbers to disk SAS WWNs (Log Info 0x31120303)
Rob Logan
Rob at Logan.com
Sat Mar 16 10:50:04 EDT 2013
>
> Run lsituil.i386 as root
> (LSIUtil Kit 1.63.zip\Solaris\lsiutil.i386 from http://www.juhonkoti.net/media/LSIUTIL-1.63.zip )
> * Select your MPT device
> * e (Enable expert mode in menus)
> * 20 (Diagnostics)
> * 1 (Inquiry Test)
> * 0 (Bus 0)
> * XX (Target number from above, Target 20 for me)
> * 0 (Lun 0)
> * 83 or 80 (SAS WWN and Disk Serial Number respectively)
cool! another closed tool is hd
http://docs.oracle.com/cd/E19432-01/820-1120-22/chapter2.html
http://rob.com/lancair/2013.03/hd.bz2
# ./hd
Device Serial Vendor Model Rev Temperature
------ ------ ------ ----- ---- -----------
c0t0d0p0 9VP6JXKT ATA ST31000528AS CC3E 36 C (96 F)
c1t0d0p0 550129060AGN ATA INTEL SSDSC2CW06 400i 255 C (491 F)
c1t1d0p0 55016H060AGN ATA INTEL SSDSC2CW06 400i 255 C (491 F)
c1t2d0p0 Z1N36V7B ATA ST1000NM0011 SN03 36 C (96 F)
c1t3d0p0 Z1N35VKL ATA ST1000NM0011 SN03 38 C (100 F)
c1t4d0p0 Z1N36WXN ATA ST1000NM0011 SN03 32 C (89 F)
c1t5d0p0 Z1N36W93 ATA ST1000NM0011 SN03 32 C (89 F)
c0t0d0p0 is on
01:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS (rev 08)
while the others are on
00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family SATA AHCI Controller (rev 05)
Rob
More information about the OmniOS-discuss
mailing list