[OmniOS-discuss] Parity error on path mpt_sas2
Dominik Hassler
hasslerd at gmx.li
Tue Dec 9 15:51:03 UTC 2014
Chip,
when I had to reflash an onboard LSI2308 I used the UEFI shell. No
fiddling around with boot disks etc.
Not sure, if it is applicable to your problem.
On 12/09/2014 03:49 PM, Schweiss, Chip wrote:
> I'm still fighting this.
>
> Under OmniOS the erase function is disabled in sas2flash for solaris.
>
> I couldn't seem to find an iso bootable DOS that I could stage files
> in. FreeDOS1.0 won't mount the CD, 1.1 got rid of the live mode.
> Tried a Linux rescue CD and I get " ERROR: Erase Flash Operation
> Failed!" Tried both P18 sas2flash and P20 sas2flash.
>
> What OS environment are you running this in?
>
>
>
> On Tue, Dec 9, 2014 at 3:06 AM, Filip Marvan <filip.marvan at aira.cz
> <mailto:filip.marvan at aira.cz>> wrote:
>
> Hi,____
>
> __ __
>
> first you have to erase P20 firmware with:____
>
> __ __
>
> sas2flsh -o -e 6____
>
> __ __
>
> now do not reboot(!) and flash P18 with____
>
> __ __
>
> sas2flsh -f XXXXXX.bin -b mptsas2.rom____
>
> __ __
>
> Filip____
>
> __ __
>
> __ __
>
> *From:*OmniOS-discuss
> [mailto:omnios-discuss-bounces at lists.omniti.com
> <mailto:omnios-discuss-bounces at lists.omniti.com>] *On Behalf Of
> *Schweiss, Chip
> *Sent:* Monday, December 08, 2014 08:09 AM
> *To:* Filip Marvan
> *Cc:* omnios-discuss at lists.omniti.com
> <mailto:omnios-discuss at lists.omniti.com>
> *Subject:* Re: [OmniOS-discuss] Parity error on path mpt_sas2____
>
> __ __
>
> I've got some new LSI HBAs I'm trying to downgrade from firmware
> version 20 to 18.____
>
> I'm getting errors when trying to downgrade:
>
> Attempting to flash firmware to LSI SAS SAS2308_2(D1) :
>
> Executing Operation: Flash Firmware Image
>
> Firmware Image has a Valid Checksum.
> Firmware Version 18.00.00.00
> Firmware Image compatible with Controller.
>
> Valid NVDATA Image found.
> NVDATA Version 11.00.00.00
> Checking for a compatible NVData image...
>
> NVDATA Device ID and Chip Revision match verified.
> ERROR: Cannot downgrade NVDATA version 14.00.00.06
> to 11.00.110000.00.
>
> ERROR: Failed to get valid NVDATA image from File!
>
> Firmware Image Validation Failed!____
>
> Tried downgrading bios:
>
> Attempting to flash Boot Service to LSI SAS SAS2308_2(D1) :
>
> Validating BIOS Image...
>
> BIOS Header Signature is Valid
>
> BIOS Image has a Valid Checksum.
>
> BIOS PCI Structure Signature Valid.
>
> BIOS Image Compatible with the SAS Controller.
>
> Attempting to Flash BIOS Image...
>
> BIOS Version in flash : 07.39.00.00
> BIOS Version from File : 07.35.00.00
> Skipping flash since file version is not greater
> than existing.
>
> Flash BIOS Image Failed!____
>
> I've tried sas2flash from P20 and P18.
>
> Can someone fill me in on the trick to downgrade? ____
>
> -Chip____
>
> __ __
>
> __ __
>
> On Thu, Nov 27, 2014 at 9:03 AM, Filip Marvan <filip.marvan at aira.cz
> <mailto:filip.marvan at aira.cz>> wrote:____
>
> Thank you for your help Aaron! I downgraded firmware to P18 and
> there are no more errors today.____
>
> It seems, that there is something bad with P20 firmware!____
>
> ____
>
> You saved me a lot of time J____
>
> ____
>
> Filip____
>
> ____
>
> ____
>
> *From:*Aaron Curry [mailto:asc1111 at gmail.com
> <mailto:asc1111 at gmail.com>]
> *Sent:* Tuesday, November 25, 2014 5:46 PM
> *To:* Filip Marvan
> *Cc:* Dan McDonald; omnios-discuss at lists.omniti.com
> <mailto:omnios-discuss at lists.omniti.com>
> *Subject:* Re: [OmniOS-discuss] Parity error on path mpt_sas2____
>
> ____
>
> I had this exact same problem recently when setting up a new home
> server... same controller, same firmware (P20). The errors were on
> all disks attached to the controller, but only on high read
> activity. Writes did not generate the errors. I downgraded the
> firmware to P18 (which is what we are using at work) and the errors
> went away. Has anyone had success with this controller and the P20
> firmware?____
>
> ____
>
> Aaron____
>
> ____
>
> On Tue, Nov 25, 2014 at 8:30 AM, Filip Marvan <filip.marvan at aira.cz
> <mailto:filip.marvan at aira.cz>> wrote:____
>
> Hi Dan,
>
> thanks for reply.
> Yes, errors are on all 5 disks in the same RAIDZ pool. No
> problem on other
> disks in different pool but on the same SAS cable.
> So maybe I only had bad luck with that disks.
>
> Filip
>
>
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> <mailto:OmniOS-discuss at lists.omniti.com>
> http://lists.omniti.com/mailman/listinfo/omnios-discuss____
>
> ____
>
>
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com <mailto:OmniOS-discuss at lists.omniti.com>
> http://lists.omniti.com/mailman/listinfo/omnios-discuss____
>
> __ __
>
>
>
>
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: 0xF9ECC6A5.asc
Type: application/pgp-keys
Size: 2686 bytes
Desc: not available
URL: <https://omniosce.org/ml-archive/attachments/20141209/783d64df/attachment.bin>
More information about the OmniOS-discuss
mailing list