[OmniOS-discuss] panic: bd_strategy after new loader installed
Dan McDonald
danmcd at kebe.com
Thu Jun 1 20:45:41 UTC 2017
On Thu, Jun 01, 2017 at 01:01:49PM -0700, Paul B. Henson wrote:
> > From: Geoff Nordli
> > Sent: Tuesday, May 30, 2017 7:57 PM
> >
> > Right, it will not boot after upgrading to the new loader; even if the
> > 4K disks are not part of the rpool.
>
> Yikes 8-/, I'm glad I hadn't got around to updating; my data pool consists
> of 13 WD Red 3TB drives which are 4K native. I'm surprised this deficiency
> wasn't noticed during development or testing, aren't 4K native drives fairly
> common nowadays? I deployed my pool back in 2009.
WAIT A MINUTE. I thought it wasn't 4k, but "4K" that actually had more bytes
on them (some sort of T.10 thing).
I'm on the road right now, but I'm pretty sure I have 4k data disks and I'm
on 022 + loader Just Fine (TM).
Here's the relevant mail:
http://lists.omniti.com/pipermail/omnios-discuss/2017-May/008906.html
I can confirm/deny this when I get home.
Dan
More information about the OmniOS-discuss
mailing list